Aerosols in Malaysia: Category 1 Until You Prove Otherwise
If you supply an aerosol in Malaysia and you have not put it through the flammability classification procedure, Malaysia's code of practice tells you what it is:
Aerosols not submitted to the flammability classification procedures in this hazard class should be classified as extremely flammable (Category 1).
Not "unclassified". Not "pending". Category 1 — the most severe category in the class. The absence of test data is itself the answer, and it is the harshest answer available.
That single default drives most of what follows: your signal word, your pictogram, your precautionary statements, and whether an imported artwork can be used in Malaysia at all.
This is a pre-screening overview, not a classification. Verify against the current Regulations and the ICOP CHC, and have classification carried out on your actual formulation.
Which rules apply, and when
Aerosols supplied for use at a place of work fall under the Occupational Safety and Health (Classification, Labelling and Safety Data Sheet of Hazardous Chemicals) Regulations 2013 [P.U.(A) 310/2013] — the CLASS Regulations — with the technical detail in the Industry Code of Practice on Chemicals Classification and Hazard Communication (ICOP CHC), promulgated under section 37 of the Occupational Safety and Health Act 1994.
The channel matters. The Department of Occupational Safety and Health states in its CLASS FAQ that it enforces the Regulations for chemicals supplied for use at a place of work only, that the consumer sector falls under the Ministry of Domestic Trade and Consumer Affairs, and that a consumer product supplied for use at workplaces must comply with CLASS.
For an aerosol brand, that usually means both. A spray lubricant sold in hardware retail and in 24-can cartons to a workshop is one product in two regimes.
What counts as an aerosol
The ICOP CHC definition is specific enough to settle arguments about pump sprays and squeeze bottles:
Aerosols, this means aerosol dispensers, are any non-refillable receptacles made of metal, glass or plastics and containing a gas compressed, liquefied or dissolved under pressure, with or without a liquid, paste or powder, and fitted with a release device allowing the contents to be ejected as solid or liquid particles in suspension in a gas, as a foam, paste or powder or in a liquid state or in a gaseous state.
Three elements have to be present: non-refillable, a gas under pressure, and a release device. A trigger-pump bottle has no gas under pressure, so it is not an aerosol — though its contents may still classify on their own as a flammable liquid.
How flammability is decided
Under the ICOP, an aerosol is considered for classification as flammable if it contains any component classified as a flammable gas, flammable liquid or flammable solid. Two notes narrow this usefully: flammable components do not cover pyrophoric, self-heating or water-reactive substances, "because such components are never used as aerosol contents"; and flammable aerosols "do not fall additionally within the scope of flammable gases, flammable liquids or flammable solids."
That second note prevents double classification. An aerosol containing a flammable liquid is a flammable aerosol — not also a flammable liquid.
The category is then decided on the components, the chemical heat of combustion, and where applicable test results:
- the foam test, for foam aerosols;
- the ignition distance test and enclosed space test, for spray aerosols.
The chemical heat of combustion is the theoretical heat of combustion multiplied by a combustion efficiency, "usually less than 1.0 (a typical combustion efficiency is 0.95 or 95%)".
Skip those procedures and you are back at the default: Category 1.
Note also that aerosols sit inside a wider set. CLASS covers sixteen physical hazard classes, among them flammable aerosols (Categories 1 and 2) and gases under pressure — compressed, liquefied, refrigerated or dissolved gas — which is a separate class with its own pictogram and statements. A non-flammable propellant does not exempt the can from the pressure side.
The transport classification is not the label classification
The ICOP's comparison table between the Regulations and the UN transport rules records that aerosols are designated as UN1950 (aerosol) and Class 2 (Gas) for transport purposes.
This is the single most expensive confusion in aerosol artwork. The transport diamond and the GHS hazard pictogram are different systems, with different symbols, different colour rules and different legal bases. Your freight documentation needs UN1950. Your label needs the GHS pictogram set — and Malaysia is strict about which one.
The label: six elements, and a concession most aerosols qualify for
Subregulation 8(1) requires every packaging of a hazardous chemical to be labelled legibly and indelibly with six elements:
- product identifier
- supplier identification
- signal word
- hazard statement
- hazard pictogram
- precautionary statement
This duty sits on both principal and subsidiary suppliers — so an importer and the distributor repacking cartons both carry it.
Then subregulation 8(2) gives a genuine concession that applies to a large share of aerosol stock-keeping units. For a container of 125 ml or less, the supplier may label with only:
- product identifier
- supplier identification
- signal word
- hazard pictogram (if applicable)
- "read SDS before use"
Hazard statements and the full precautionary set can come off a small can. If your range straddles the 125 ml line, that is two different label specifications, not one.
The rules that fail imported artwork
Red border, always. Regulation 9 specifies the pictogram as a black symbol on a white background with a red border, in a diamond shape with sides tilted at 45 degrees to the horizontal. DOSH's FAQ is categorical on the alternative: asked whether suppliers may use labels with black-border pictograms, the answer is "No. CLASS Regulations only allow the use of red border pictograms." Artwork printed to a black-and-white convention, or carrying transport-style diamonds, does not comply.
Pictogram size. Each pictogram must be one-fifteenth of the area of the label, but not less than 100 mm². DOSH clarifies that this applies to each pictogram individually, that the label surface considered is the surface carrying the information required by subregulations 8(1) and (2), and that additional information such as a purchase number is not counted in the label-size calculation.
Minimum label size. Regulation 11 and the Fourth Schedule set a minimum label dimension that steps up across four capacity bands — packages not exceeding 3 litres, greater than 3 but not exceeding 50 litres, greater than 50 but not exceeding 500 litres, and greater than 500 litres. Check your pack volume against the Schedule before anyone shrinks the artwork to fit a design.
Two languages. Subregulations 8(3) and (4) require the information to follow the hazard classification, pictogram, signal word and hazard statement in the First Schedule, to be in accordance with Part 3 of the ICOP CHC, and to be supplied in the national language and English.
One signal word. Where "Danger" is used, "Warning" must not be used. A Category 1 flammable aerosol carries Danger — so a bilingual label that also prints Warning somewhere is defective.
Spare pictogram boxes. Many imported cans are printed with a row of empty diamonds for market-by-market use. DOSH's FAQ allows them to be covered wholly with the same colour as the background, blacked out so the diamond shape is no longer visible, or marked "No GHS Pictogram". What is not allowed is leaving them blank, or blackening them in a way that still shows the diamond.
Precautionary statement count. The maximum on the label is six, unless more are necessary to reflect the nature and severity of the hazard — and the statements used must be those listed in the ICOP CHC, not the revised wording from a later GHS edition.
Background colour. A coloured background is acceptable provided it does not camouflage the text — but the background of the pictogram itself must be white.
Whose name goes on it. Two company names are permitted. Per DOSH: the details of the local supplier are mandatory; the details of the overseas manufacturer are optional.
Affixing. Regulation 12 requires the label to be firmly affixed to at least one surface so that it can be read horizontally when the package is set down in its normal position. For containers of 125 ml or less, it may be affixed as the supplier reasonably deems appropriate; where labelling is impracticable given the nature of the container, it shall be tagged.
The three-month clock on reclassification
Subregulation 8(7) requires the label to be updated within three months where a change results in a more severe classification.
For aerosols this is a live risk, because reformulating the propellant or the solvent can move the category. Three months is not long for artwork revision, plate changes, and the stock already printed.
A pre-print checklist for an aerosol line
- Confirm the channel. Workplace supply means CLASS; consumer retail is a different regime, and both may apply.
- Have the formulation classified properly, with the foam or ignition-distance and enclosed-space tests as applicable. Skipping this assigns Category 1 by default.
- Check the pressure side separately — gases under pressure is its own hazard class.
- Split your SKUs at 125 ml. The small-container concession changes the label content.
- Verify pictograms are black symbol, white background, red border, diamond at 45°.
- Size each pictogram at 1/15 of the information-bearing label surface, never below 100 mm².
- Check pack volume against the Fourth Schedule minimum label dimensions.
- Deal with spare pre-printed diamonds — cover, black out fully, or mark "No GHS Pictogram".
- Cap precautionary statements at six, taken from the ICOP CHC list.
- Malay and English, with the prescribed phrases in both. "Danger" or "Warning", never both.
- Local supplier identification present.
- Keep UN1950 on the transport paperwork and out of the hazard-communication label.
Frequently Asked Questions (FAQ)
Q: What happens if we never tested our aerosol for flammability? The ICOP CHC states that aerosols not submitted to the flammability classification procedures should be classified as extremely flammable, Category 1. The absence of testing produces the most severe classification rather than no classification.
Q: Is a pump spray bottle an aerosol under CLASS? No. The ICOP definition requires a non-refillable receptacle containing a gas compressed, liquefied or dissolved under pressure, fitted with a release device. A pump bottle has no gas under pressure — though its contents may classify as a flammable liquid in their own right.
Q: Can we use the UN1950 transport diamond as our hazard label? No. UN1950 and Class 2 (Gas) are transport designations. The label under CLASS requires GHS pictograms — black symbol, white background, red border — and DOSH states that only red-border pictograms are allowed.
Q: Our cans are 100 ml. Do we need the full label? Subregulation 8(2) allows a container of 125 ml or less to carry only the product identifier, supplier identification, signal word, hazard pictogram if applicable, and "read SDS before use".
Q: What do we do with the empty pictogram boxes printed on imported cans? DOSH allows them to be covered wholly in the background colour, blacked out so the diamond shape is no longer visible, or marked "No GHS Pictogram". Leaving them blank, or blacking them while the diamond remains visible, is not allowed.
Q: How many precautionary statements can we print? A maximum of six, unless more are necessary to reflect the nature and severity of the hazard, and they must be the statements listed in the ICOP CHC.
Before the cans are printed
Aerosol artwork is the most densely regulated label surface in the general-goods category: six elements or five, two languages, a pictogram with a specified colour and a specified fraction of the label area, and a hard minimum size tied to pack volume.
Run your draft through our free label check before the print run.
Related reading: Malaysia's CLASS Regulations: classification, labelling and SDS · Why your supplier's SDS will not pass · Household cleaning products and chemicals labelling
📚 Sources / official references
- Occupational Safety and Health Act 1994 [Act 514], Laws of Malaysia — Attorney General's Chambers (the CLASS Regulations 2013 [P.U.(A) 310/2013] are made under paragraph 66(2))
- Subsidiary legislation index — P.U.(A) 310/2013, Occupational Safety and Health (Classification, Labelling and Safety Data Sheet of Hazardous Chemicals) Regulations 2013, gazetted 11 October 2013
- Frequently Asked Questions for CLASS Regulations (FAQ CLASS) — Department of Occupational Safety and Health, Malaysia
- Department of Occupational Safety and Health (DOSH / JKKP), Malaysia
This article is compiled from the official sources above for reference only; actual compliance is subject to the authorities' latest regulations and review.
Find out what your label is missing
Free label check →